The device adopts an imported sensor core that converts liquid level pressure signals into corresponding digital signals. These are processed by digital circuits and output as a standard two-wire RS485 signal. The integrated design encapsulates the isolated sensor and digital processing circuit within the probe, directly outputting RS485 signals via a specialized cable.
Open water tanks and water towers
Rivers, lakes, wells, dams, and groundwater monitoring
Urban water supply and wastewater treatment
Hydraulic engineering, irrigation, and flood control monitoring
Fuel tanks of diesel generators and hydropower equipment
Alcohol and other organic solvent level monitoring
High-performance sensor with digital signal processing and stainless steel construction
Advanced moisture protection with IP68 rating and reliable waterproof sealing
Durable polyurethane cable, resistant to water, oil, and complex media
Automatic pressure and temperature compensation
Compact, robust, corrosion-resistant, overload-protected, and easy to use
Optional lightning protection module available upon request
Model | LS WL-1EMWEG |
Range | 0m~10m~30m~500m |
Overload Pressure | Three times the maximum range |
Pressure Type | Gauge pressure or absolute pressure |
Load Voltage | 250 ohms |
Accuracy | ±0.1%FS±0.25%FS +0.5%FS |
Measurement Error | ≤±3cm |
Adaptation to Water Level Change Rate | ≤40cm/min |
Response Frequency | Analog signal output ≤500HZ, digital signal output ≤5Hz |
Long-term Stability | ±0.1%FS/year |
Temperature Compensation | -10~60°C |
Medium Temperature | -35~85°C (ambient type) |
Storage Temperature | -35~125°C |
Operating Voltage | 3~5V DC 10~36V DC |
Output Signal | 4~20mA DC 0~20mA DC 0/0.5/1~2.5/3/4.5/10V DC RS485 |
Transmission Method | Two-wire system Three-wire system Three-wire system Four-wire system |
Protection Level | IP68 |
Shock Resistance | 10g (20...2000Hz) |
Electrical Connection | Connector or cable output |